Data centre cooling plant rooms, built offsite

Prefabricated chilled-water plant rooms, pump skids and heat exchanger modules for data centre operators, developers and their delivery teams. Designed for redundancy, tested before dispatch, installed in short site windows.

Illustration of a data centre building with rooftop heat rejection and a prefabricated plant enclosure
Data centre with prefabricated plant enclosure · Illustrative render
N+1 / 2NRedundancy designed in
FATFactory acceptance testing
Concurrent maintenanceIsolation for live service
BMS / EPMSPoints list and integration

Overview

Cooling plant that arrives ready, on programme

Data centre programmes are driven by energisation and handover dates. Site-built mechanical plant competes for space, labour and time with electrical fit-out. Prefabricating the cooling plant moves fabrication, welding and pressure testing into the workshop and leaves site teams with set-down and connection.

We design and build the plant around the cooling strategy: air-cooled chillers, dry coolers with free cooling, evaporative heat rejection, or liquid cooling to the rack.

  • Duplicated plant and isolation for maintenance without loss of cooling
  • Repeatable modules for phased data hall roll-out
  • Factory acceptance testing witnessed before delivery
  • Documentation to support Level 1 to Level 5 commissioning
Illustration of chilled-water pumps, plate heat exchangers and insulated pipework in a cooling plant room
Chilled-water pumps and plate heat exchangers. Illustrative render, not a project photograph.

Scope

Data centre plant we build

Chilled-water plant rooms

Primary and secondary pumping, buffer vessels, headers, pressurisation and controls in an external enclosure serving chillers or dry coolers.

Pump skids

Duty, assist and standby pumps on inverters, with isolation, non-return valves, strainers and flow measurement.

Free cooling and heat exchange

Plate heat exchanger skids for economiser operation and hydraulic separation between glycol and water circuits.

Liquid cooling loops

Technology cooling system skids and secondary loops serving coolant distribution units for direct-to-chip cooling.

Heat recovery

Heat pump and heat exchanger plant that recovers data hall heat for campus buildings or export to a heat network.

Water quality

Side-stream filtration, dosing, degassing and monitoring to protect plate heat exchangers and cold plates.

Resilience

Redundancy and maintainability

Topology is agreed with the operator and design team before fabrication starts.

ArrangementWhat it means in the plant roomTypical use
NPlant sized to the load, no spareNon-critical or ancillary cooling
N+1One additional pump, heat exchanger or chiller connection on each duty setMost enterprise and colocation halls
2NTwo fully independent systems, A and B, each able to carry the full loadCritical halls and high-density AI deployments
Concurrently maintainableValving, bypasses and dual paths so any component can be isolated without loss of coolingOperators targeting high-availability design standards

Delivery

Built for the data centre programme

  1. Design freeze: schematics, GA drawings, load and redundancy confirmed, points list issued.
  2. Fabrication: plant, pipework, insulation, electrics and controls built in parallel with site works.
  3. FAT: pressure and functional testing, witnessed by the client team.
  4. Delivery: lift plan and logistics agreed with the principal contractor; set-down in planned windows.
  5. Commissioning: flushing, water treatment, controls set-up and support for integrated systems testing.
Discuss a data centre project
Twin circulating pumps with pressure gauges and flanged pipework built offsite
Pump sets and header pipework built in the workshop (heating project).
What do you supply for data centre cooling?

Prefabricated chilled-water plant rooms, primary and secondary pump skids, plate heat exchanger skids for free cooling and heat recovery, technology cooling system (TCS) loops for liquid cooling, buffer vessels, pressurisation, water treatment and filtration. Chillers and dry coolers can be specified by us or supplied by others and integrated.

Can you design for N+1 or 2N redundancy?

Yes. Redundancy is set at design stage: N+1 pumps and heat exchangers, dual headers or fully separate A and B systems, with isolation arranged so plant can be maintained without loss of cooling.

Do you support factory acceptance testing?

Yes. Pressure tests, functional tests of pumps, valves and controls, and points-to-points with the BMS can be witnessed in the workshop before delivery, ahead of site commissioning and integrated systems testing.

Can you work to an operator's or consultant's design standards?

Yes. We work to the client's employer's requirements, M&E consultant specifications and operator standards, and issue drawings, schematics and points lists for approval before fabrication.

Do you also supply heating plant for data centre campuses?

Yes. Packaged gas or heat pump plant rooms for offices, welfare and ancillary buildings, and heat recovery plant that uses data hall heat for buildings or heat networks.